Measuring pedal actuating forces

The actuating forces applied to pedals under different operating conditions are measured during test drives on the road and in the driving simulator...

Calibration Instruments

Model
Calibration instrument
7281
Mobile high-precision calibrator and testing device for mechanical and electrical measurements

Measurement accuracy: < ± 0.001 % F.S.

9206
USB multisensor interface

Measurement accuracy: 0,01 % v.E.

Sample rate: 1200/s

Type of sensor: Strain gauge; Potentiometer; DC/DC; Pt100

9405
Product Discontinuation from 1st Jan. 2020 - Alternative 7281

Bridge resistance: 350 Ω ± 1 %

Calibration steps: (±) 0; 0.5; 1; 1.5; 2; 3 mV/V

Electrical connection: 4 mm ...

72-9206-REF
Portable Precision USB Sensor Interface

Messrate: 1200/s

Sensortyp: Strain gauge; potentiometric; DC/DC; Pt100

72-REF
Portable Reference Measuring Chain with DKD/DAkkS Calibration Certificate for Compression Load from 20 N to 100 kN

Measurement accuracy: < ± 0.001 % ...

1240
Calibration resistor

Resistance value: 10 μΩ ... 100 kΩ

Tolerance: < ± 0.02 %

Temperature coefficient: ≤ ± 10 ppm/K

Storage stability: < ± 0.01 % over years

1282
Precision high capacity resistor

Resistance value: 1 mΩ ... 100 mΩ

Tolerance: 0.02 %

Temperature coefficient: ≤ ± 10 ppm/K

Storage stability: < 0.01 % over years

114X
116X
High-precision resistors

Resistance value: 5 Ω ... 100 kΩ

Tolerance: ± 0.02 % or ± 0.05 %

Temperature coefficient: < ± 10 ppm/K

Storage stability: 0.02 % over years

1144-Pt
1146-Pt
Platinum Resistance Thermometer Simulation

Temperature values: -200 ... +800 °C 

Tolerance: ± 0.02 % or ± 0.05 %

Temperature coefficient: < ± 10 ppm/K

werkskalibrierschein wks kalibrierschein vor ort on site kalibrierung factory calibration burster
72KME
Portable Load Cell Calibration

You can calibrate your load cells and load cell based measurement systems with our Portable Load Cell Calibration Stand. It measures with ...

1427
Computer-controlled high-precision resistance decade

Resistance range: 1.0000 ... 1.200000 MΩ

Tolerance: 0.005 %

1406
1407
High-precision resistance decade and calibrator

Resistance range: 10 mΩ ... 1 MΩ

Tolerance: from 0.02 %

Temperature coefficient: ≤ 10 ppm/K

Storage stability: < 0.02 % over years

4530
Precision RTD simulator

Pt100 simulation range: -200.000 ... 850.000 °C

Measurement accuracy: 0.02 °C

Pt200, Pt500, Pt1000 simulation: Yes

4501
Digital Pt100 simulator

Pt100 simulation range: -100 ... +500 °C

Measurement accuracy: ± 0.5 K

Pt200, Pt500, Pt1000 simulation: No

Ni100, Ni100 simulation: No

4506
4506S
Precision Pt100 simulator

Pt100 simulation range: -100 ... +500 °C

Measurement accuracy: ± (0.082 + 0.0003 x t) in °C

4462
High-precision calibration source for voltage, current and thermocouple

DC voltage simulation: 1 μV ... 30 V
(60 V)

4420
Universal calibrator

DC voltage simulation: ±9.999 mV ... ±11.000 V

Measurement accuracy voltage simulation: ≤ 0.02 % F.S.

4423
Documenting universal calibrator

Product no longer available.

We recommend DIGISTANT® 4420 and/or TRANS CAL 7281 depending on your application.

Riferimenti

Richiedi prodotto

    Confronta prodotto

      COILTECH 2019

      Venite a trovarci!
      COILTECH 2019
      25-26  Settembre - Pordenone (PN)

      Scopri i nostri nuovi prodotti!

      Scopri la nostra nuova brochure Celle di carico per produzione, automazione, R&D e controllo qualità con molti esempi applicativi e informazioni focalizzate sul prodotto!

      Scarica la nostra nuova brochure

      Scoprite la nuova brochure Press-fitting - the reliable way. Controllo di qualità al 100% per le operazioni di pressatura manuale con molti esempi applicativi e informazioni focalizzate sul prodotto!

      Download our new brochure

      Scoprite la nostra nuova brochure Torque Sensor con molti esempi applicativi e informazioni focalizzate sul prodotto!

      Download our new brochure

      © 2019 // burster Italia s.r.l.
      nach