Test measurement technology for complete quality assurance

in mass battery production

  • Testing of 32 Li-ion round cells from a complete battery module at EoL (without BMS electronics)
  • Timely detection of possible causes of failure such as self-heating, capacity losses or accelerated aging processes
  • Preventing serious impacts on battery life   

 

TASK

Determining the open-circuit module voltage, using the four-wire measurement method the AC/DC internal resistance is measured at 1 kHz and 10 Hz, in order to draw conclusions about the electrolyte and electrode properties. The measured values and evaluation results are transferred to the PLC via PROFINET. Due to their minimal dimensions, IP54 protection and low weight, the modules are installed in the immediate vicinity of the robot.

Measuring and evaluation parameters
Ucell ……………. approx. 3.66 … 3.67 VDC
Umodule ………… approx. 58.62 … 58.82 VDC
RAC (1 kHz)……. approx. 23.50 … 24.88 mΩ
RDC (10 Hz)…… approx. 1.75 mΩ

Go to product 2511

Sectors

Contactpersons

burster in Malta

Malta

burster Italia S.r.l.

Via Repubblica, 10
24035 Curno
Italy

Fon: +309 035 618120
Fax: +39 035618250
infoburster.it
www.burster.it

SERVICES

  • Qualified design, application support
  • Process optimization
  • Qualified integration support & training
  • On-site trouble shooting
  • Qualified phone & online support
  • Local calibration service
×

Product Inquiry

    Product comparison

      Brandnew Brochure: Load cells

      Discover our new brochure Load cells for production, automation, R&D and quality assurance with many application examples and product focused information!

      Download our new brochure

      © 2024 // burster Italia s.r.l.
      nach oben