TRANS CAL 7281 Calibratore portatile ad alta precisione e dispositivo di prova per misure elettriche e meccaniche

Dispositivo di prova, simulatore di strain gauge, test del sensore, catena di miusra campione

  • Features

    • Sensori supportati: Strain gauge/segnale normalizzato ± 5V, ± 10 V, sensori potenziometrici
    • Test del dispositivo: Simulatore di Strain gauge fino a ± 50 mV/V
    • Easy adjustment through burster TEDS
    • Eccellente linearità con non-linearity < ± 0.001 %
    • Memoria fino a 16 programmi di misura
    • Data logger fino a  30.000 misurazioni
    • Certificato di calibrazione burstr e / o Certificato di calibraizone tracciabile con standard Tedesco DKD / DakkS opzionale disponibile per il solo sturmento / intera catena di misura
  • Product data

    Model 7281
    Measurement accuracy < ± 0.001 % F.S.
    Sample rate

    0.1 … 1200/s (DC)
    0.1 … 2/s (AC)

    Type of sensor
    • Strain gauge
    • Potentiometer
    • Transmitter
    • Sensors and devices with voltage output
    Interfaces USB 2.0
    Sensor excitation

    Strain gauge:

    • DC: 2.5 V / 5 V (for 120 Ω only 2.5 V)
    • AC: 2.5 Veff / 5 Veff (from 350 Ω)

    Potentiometer:

    • 5 VDC

    Transmitter:

    • 12 VDC ± 5 %
    Protection class IP40
    Supply voltage 10 ... 28 VDC
    Reference measurement device Yes
    Sensor test Yes
    Device test Yes
    Strain gauge simulator Yes
    Data logger Yes
    Electronic sensor data sheet Yes
    Connection type 4 / 6 wire connection
    Measurement programs 16
    Specific characteristics
    • Device test: Strain gauge simulator up to ± 50 mV/V
    • Easy adjustment through burster TEDS
    • Storage of up to 16 measurement programs
    • Data logger for up to 30.000 measurements
    • Factory calibration certificate and / or German accredited DKD / DakkS calibration certificate optionally available for the instrument / entire measurement chain
  • Description

    The multipurpose digital indicator TRANS CAL 7281 can be used wherever there is a need to perform high-precision, in-situ calibrations of sensing components used in equipment such as presses, torque tools or pressure-regulating systems. An optional factory calibration certificate or German-accredited DKD/DAkkS calibration certificate can be provided when the measurement device needs to be used as a reference. This provides a quick and cost-effective way of assessing a system with traceable documentation of measurement results.

    If a reference measurement cannot be made because the sensor location is difficult to access, it is still possible to test the zero point, the input, output and isolation resistance as well as the calibrating offset of the fitted sensor. It is also possible to check the indicating device by measuring the excitation voltage and simulating the characteristic values (mV/V or V) of the sensor used.

    The instrument is used in metrology institutes, calibration laboratories and in industry in the fields of quality assurance, facility commissioning and system monitoring.

    Areas of use:

    1. Checking hydraulic presses
    2. Reference measurements in assembly lines
    3. Test of robotic pressing forces
    4. Calibrating test equipment
    5. Calibrating of high-precision measuring devices

    The TRANS CAL 7281 can be fitted with standard or rechargeable batteries for portable use or can run from an external power supply. Combined with a reference sensor the testing device provides a high-precision reference measurement chain e.g. for force measurements, but is also ideal for service engineers as a tool for locating faults in device or sensors.

    The choice of sensors includes strain gauge, normalizedsignal ± 5 V / ± 10 V and potentiometric sensors. The LCD graphics display shows the live measurement value and the corresponding bar indicator. It also supports display functions such as data-logger, tared value in % and upper/lower limit for the comparator with simultaneous indicator (< = >) of the evaluation result.

    For routine testing and also fault-locating tasks, the tester makes it really simple to measure isolation resistances and input/output resistances. The equipment test function is a quick and easy way to verify that the display device complies with the characteristic value, offering strain-gage simulation of up to ± 50 mV/V or output of a normalized signal of up to 10 V. German-accredited DKD/DAkkS calibration certificates or factory calibration certificates are optionally available. The DigiCal configuration and data-acquisition software provides useful display and reporting functions.

  • Data Sheet & Downloads

    Data sheet
    Operation manual
    Software
    Further info
  • Accessories

    pdf Aluminium case for TRANS CAL 7281 and accessories
  • Videos

    Motek exhibition video burster 2015

    burster Calibration to go Control 2015


    Youtube channel Burster Youtube Channel

Related products



Riferimenti

Solutions

Lösungen Bild

Sectors

Aerospace Industry
Automotive
Machine Manufacturers
Others
Tool / Mold Construction
© 2019 // burster Italia s.r.l.
nach